View Task
2013 Takagi T-KJr2-IN
>>
Maintenance Schedule
>>
Clean water inlet filter
Description
Instructions
1. Close the manual gas shut off valve. 2. Turn off power to the unit and wait a couple of seconds. Turn on again. 3. Wait 30 seconds, and then turn off power to the unit, yet again. 4. Close the water shut off valve. 5. Open all hot water taps in the house. When the residual water flow has ceased, close all hot water taps. 6. Have a bucket or pan to catch the water from the unit’s drain plugs. Unscrew the two drain plugs (Large and small) to drain all the water out of the unit. 7. Wait a few minutes to ensure all water has completely drained from unit. 8. Clean the filter: Check the water filter located within the cold inlet. With a tiny brush, clean the water filter of any debris which may have accumulated and reinsert the filter back into the cold water inlet. 9. Securely screw the drain plugs back into place. Hand‐ tighten only.
Task Type
Preventive
Inspection
Clean
Repair
Modify
Takes asset out of service
Priority
Low
Medium
High
Estimate
Hours
This task uses no parts
Triggers
By Time
Every
Hours
Days
Months
Years
Starting At
Hours
Limit
occurences
No public attachments